Glass Insulator for Substation Equipment

Product Details
Customization: Available
Certification: CCC, CE
Color: White
Still deciding? Get samples of $ !
Request Sample
Manufacturer/Factory & Trading Company
Diamond Member Since 2010

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
20
Year of Establishment
2010-01-08
  • Glass Insulator for Substation Equipment
  • Glass Insulator for Substation Equipment
  • Glass Insulator for Substation Equipment
  • Glass Insulator for Substation Equipment
  • Glass Insulator for Substation Equipment
Find Similar Products
  • Overview
  • Essential details
  • Product Description
  • Product Parameters
  • Product introduction
  • Detailed Photos
  • Packaging & Shipping
  • Company Profile
  • FAQ
Overview

Basic Info.

Model NO.
002
Fire Rating
94V1
Size
13*
Material
Stainless Steel
Type
Releasable Cable Tie
Application
High-Voltage
Usage
High Voltage Power Transmission
Structure
All Kinds
Connection Method
All Kinds
Size of Bearing Capacity
All Kinds
Brand
Marink
Quality
High
Specification
DIN / DUE TO ORDER
Trademark
Marink
Origin
China
HS Code
3926901000
Production Capacity
5000000PCS/Week

Product Description

Essential details

Essential details

Brand Name: Marink Model Number: U70B/146, U70B/146
Type: Insulator Material: FiberGlass
Application: High Voltage, High Voltage Rated Voltage: 70KN
Product name: Glass Insulator Packing: Customized Packing
Color: Transparent    
 
Product Description

Products Description

Glass Insulator for Substation Equipment
Main features:
Our glass insulators has ball and socket coupling,designed and tested according to IEC standard.
Disc glass insulators are connected to make a string used on power lines,with one end connected to poles by fittings and other end connected to conductor or cables.
The usage of such glass insulators string are mainly divided into 2 types: tension insulator string and suspension insulator string.


 

Product Parameters
Type U100B
Diameter(mm) 255
Height(mm) 146
Creepage Distance 320
SML(kN) 100
Mechanical Routine Test 50
Socket coupling(mm) 16
Wet Power Frequency Withstand Voltage(kV) 40
Dry lightning impulse withstand voltage(kV) 100
Impulse Puncture Voltage(P.U) 2.8
Power Frequency Puncture Voltage(kV) 130
Radio Influence Voltage(μv) 50
Corona visual test(kV) 18/22
Power frequency electric arc voltage(kA) 0.12s/20kA
Net weight per unit(kg) 4
 
Item Spacing(mm) Diameter(mm) Creepage Distance(mm)
U40B 110 175 190
100 175 190
U70BS 127 255 320
U70BL 146 255 320
U100BL 144 255 320
U100BS 127 255 320
U120B 146 255 320
U120BS 146 280 450
U160BL 170 280 400
155 280 400
U160BS 146 280 400
U210B 170 280 400
170 280 450
170 280 400
170 280 450
U300B 195 320 485
U400B 205 360 550
U530B 240 380 620
300 400 700
U70BLP 146 255 400
146 280 450
146 320 550
146 255 400
U100BLP 146 280 450
146 320 550
146 255 400
U120BP 146 280 450
146 320 550
155 280 450
U160BLP 170 280 450
170 320 550
155 320 550
U120BP 170 320 550
170 320 550
195 320 550
U120BP 195 360 635
240 360 635
52-3A 255 146 320
52-5A 255 146 320
52-8A 280 146 400
52-11A 280 155 400
52-4A 255 146 320
52-6A 255 146 320
52-10A 280 165 380
52-3FA 280 146 450
52-5FA 280 146 450
52-8FA 280 171 450
52-11FA 280 170 450
Product introduction


Its main performance:

1. Insulators are commonly used as a flexible coating on electric wire and cable.
Since air is an insulator, in principle no other substance is needed to keep power where it should be. High-voltage power lines commonly use just air, since a solid (e.g.,plastic) coating is impractical. However, wires which touch each other will produce cross connections, short circuits, and fire hazards. In coaxial cable the center conductor must be supported exactly in the middle of the hollow shield in order to prevent EM wave reflections.Finally, wires which expose voltages higher than 60V can cause human shock and electrocution hazards.
Insulating coatings help to prevent all of these problems.
2.  Some wires have a mechanical covering which has no voltage rating;e.g.: service-drop, welding, doorbell, thermostat. An insulated wire or cable has a voltage rating and a maximum conductor temperature rating. It may not have an ampacity (current-carrying capacity) rating, since this is dependent upon the surrounding environment (e.g. ambient temperature).
3. In electronic systems, printed circuit boards are made from epoxy plastic and fibreglass. The nonconductive boards support layers of copper foil conductors. In electronic devices, the tiny and delicate active components are embedded within nonconductive epoxy or phenolic plastics, or within baked glass or ceramic coatings.
In microelectronic components such as transistors and ICs, the silicon material is normally a conductor because of doping, but it can easily be selectively transformed into a good insulator by the application of heat and oxygen. Oxidized silicon is quartz, i.e. silicon dioxide, the primary component of glass.
4. In high voltage systems containing transformers and capacitors, liquid insulator oil is the typical method used for preventing arcs. The oil replaces the air in any spaces which must support significant voltage without electrical breakdown. Other methods of insulating high voltage systems are ceramic or glass wire holders, gas, vacuum, and simply placing the wires with a large separation, using the air as insulation.
Detailed Photos

 

Glass Insulator for Substation EquipmentGlass Insulator for Substation EquipmentGlass Insulator for Substation EquipmentGlass Insulator for Substation EquipmentGlass Insulator for Substation Equipment
Packaging & Shipping

Glass Insulator for Substation Equipment

Company Profile

Company Profile

Qingdao Marink Enterprise Co.,Ltd is the leading manufacturer of agricultural,equestrian,fencing equipments and relevant fastening parts and safety products.
You are guaranteed maximum build quality with excellent value for money. Our commitment to research, development and the investment in the most up-to-date laster cutting, robotic and profiling machinery ensure that all our products are manufactured to the highest standard at very competitive prices.
We are hard working,friendly,knowledgeable,and the responsibility to do the right things.
Our commission is to offer the right products,at the right time,at the right price,with smiles!

Glass Insulator for Substation Equipment

FAQ

Q;Are you a factory?
A:Yes we are a factory with 17 years of experience, welcome to visit our factory

Q:Do you have all colors in stock?
A:Some of the colors and designs are in stock,pls contact us to get more details.

Q:Can I have my own colors?
A: Yes,we can make it as your colors.

Q:Can I have my own logo?
A: Yes,we can make it as your drawing.

For more designs and details,please don't hesitate to contact me by email,we will reply you soon.


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier